1. Home
  2. /
  3. Blog
  4. /
  5. Apartment Plan – Factors...

Apartment Plan – Factors for design of residential apartment

LinkedIn
Share
WhatsApp
Apartment Plan Design

Key factors related to design, planning, and regulation which govern the design of an apartment plan.

Design of a plan for an apartment has now become more than art and involves a lot of maths. With strict development control regulations across cities, apartment style residential development has now become a product of the regulations. Apartment style residential development is a phenomenon of cities, specifically Tier 1 cities, in India. And is now slowly catching up with Tier 2 and Tier 3 cities of India. All Tier 1 cities have strict regulation with regards to developments, a residential development needs to follow all development parameters laid by a municipal governing body, fire requirements, environmental requirements, height restrictions and other restrictions varying from region to region and city to city. Despite all the above requirements a developer must keep a project profitable, all the costs must be loaded on the end customer. It does raise questions related to affordability of projects.

Explore on Serviced Apartment – An Architect’s comprehensive overview

Apartment Plan – Design Parameters

One can say that the apartment plan design is dependent on the following factors.

Product Type – Studio apartment, 1BHK, 2BHK etc

These are market dependent factors. Factors of local requirements, affordability, infrastructure govern the product type. Typically, as close a residential development is to a business district or commercial areas the apartment configurations are of smaller type. As more of working population would want to purchase such kind of apartments, to be close to their place of work. This working population would be ready to move in into smaller configurations of 1BHK and studio apartments. Also keeping in mind, the cost of development in such areas closer to commercial areas will be higher, owing to higher land costs. Further away in the suburbs, larger apartment configurations would be preferred such as 3BHK or even 4BHK depending on the city, and its infrastructure connectivity.

Product Configurations, Amenities Specifications

Carpet areas of flats, as required by micro markets and associated markets. This is again demand driven. Cities like Mumbai and Hong Kong now have increasing smaller 1BHK s, say upto 400 Sq.Ft and 2BHK s starting from 600 Sq.Ft. Market defines the acceptable limit of the carpet area of a flat. Other associated amenities like swimming pools, club house is now sought after in apartment complex development. And many a times is the deciding factor for purchase of a residential apartment development.

Development control regulations

FSI available for development is the main consideration from development control regulations. FSI caps the development potential for a piece of land. Other regulations dictate the minimum size of rooms, balconies, parking, open space and vehicular movement requirements. Other consideration includes concepts of free of FSI, areas which a developer can provide to end users, without bearing any development charges to municipal authorities. Of course, the developer will have to bear the cost of construction such areas / amenities. Development control regulations dictate the minimum garden areas required for a development, areas to be handed over for social developments, which shall be carried out by municipal authorities. This could include development of firefighting capabilities, dispensaries etc.

Also learn about FSI in real estate? How is FSI calculated in Mumbai?

Fire Requirements in drawing an Apartment Plan

 Fire requirements require development of accessible points for firefighting, in terms of refuge areas, fire lifts, fire towers, mechanised access for firefighting personnel depending on different heights of building proposed and related to fire requirements of different cities. Most fire requirements have now a provision of providing sprinkler system to residential system. It is common to have smoke detection system and fire alarm system in high rise developments. Apart from this the physical development in control by fire norm in terms of accessibility to building on all sides of a development, distance of the building from the tower footprint etc, number of staircase and width of these staircases. These requirements have a significant impact on the design and cost of an apartment complex development.

Sustainability Requirements

 Various green building requirements dictate the type of internal apartment design and external building development requirements. There are various green building certification bodies which direct and award certifications like IGBC, Griha, USGBC to name a few. The requirements govern factors related to environment and sustainability, for example use of low voc paints, use of solar panels, provision of electric charging, maintaining topsoil and rainwater harvesting. These design elements are incentivised in terms of points and a certificate is awarded to project based on the final tally of points achieved by the project.

Real Estate Developer requirements in a Apartment Plan

A developer requires a project to be feasible and tries to minimize wastage in terms of design. Additional, or unusable spaces in design of apartment design plan are to be avoided. Developer measures the efficiency of design with respect to construction areas. Construction areas are measured with respect to carpet areas and built up areas (FSI areas). Additionally, a developer controls the specifications for a project. My keeping the specified finishes and fitting for a project the developer achieves cost optimisation for a project. These have serious implications on apartment plan. For example, the number of units per floor is key factor which the developer decides with respect to efficiency and sale ability. The more the number of units on a floor better design efficiency for a project, by way of shared lifts and staircase. Thereby optimum cost spent on a development by the real estate developer.

Efficiency Ratios in Residential Apartment Towers

Efficiency ratios are critical benchmarks that developers, architects, and investors use to evaluate the design quality and financial viability of a residential apartment tower. These ratios directly impact the saleable area, construction cost, and ultimately the profitability of a project. The key efficiency ratios in residential apartment towers are outlined below.

1. Carpet Area to Construction Area Ratio

The Carpet Area to Construction Area ratio (also referred to as the Loading Factor or Efficiency Ratio) measures how much of the total constructed area of a tower is actually usable by the apartment occupant. It is one of the most important design efficiency indicators for a residential tower.

Formula:
Carpet Area to Construction Area Ratio (%) = (Total Carpet Area ÷ Total Tower Construction Area) × 100

Benchmark Ratios for Residential Towers:

Project TypeTypical Carpet / Construction Area Ratio
Affordable Housing72% – 78%
Mid-segment Residential68% – 74%
Premium / Luxury Residential62% – 70%
High-rise Tower (30+ floors)60% – 68%

A higher ratio indicates better design efficiency — meaning more area is delivered to the buyer per square foot of construction. Luxury towers tend to have lower ratios due to larger common lobbies, wider corridors, double-height spaces, and premium amenity areas. The ratio is impacted by the number of apartments per core, corridor widths, lift lobby sizes, and staircase configurations. Optimising the number of units served per lift and staircase core is the primary lever to improve this ratio.

2. Carpet Area to FSI Area Ratio

The Carpet Area to FSI (Built-up) Area ratio reflects how much of the permissible FSI area is converted into net saleable carpet area. This ratio is particularly relevant from a revenue and feasibility standpoint, as FSI area is the regulated development quantum and carpet area is what is sold to homebuyers under RERA.

Formula:
Carpet Area to FSI Area Ratio (%) = (Total RERA Carpet Area ÷ Total FSI / Built-up Area) × 100

Benchmark Ratios:

Project TypeTypical Carpet / FSI Area Ratio
Affordable Housing75% – 82%
Mid-segment Residential70% – 78%
Premium / Luxury Residential65% – 72%

This ratio is closely linked to the definition of FSI area under local development control regulations. In Mumbai (DCPR 2034), for example, certain areas such as balconies, flower beds, and utility areas may be counted partially or fully in FSI, which affects this ratio. Fungible FSI provisions, where applicable, can also increase the total construction area beyond the base FSI, slightly reducing this ratio while allowing more saleable area overall.

Also learn about FSI in real estate? How is FSI calculated in Mumbai? and Real Estate and Construction Terminologies

3. Car Parking Efficiency

Car Parking Efficiency is a measure of how efficiently the parking area in a development is designed to accommodate each car. It is expressed as the total parking construction area (including drive aisles, ramps, columns, and structural area) divided by the number of car parking spaces provided.

Formula:
Car Parking Efficiency (Sq.Ft per car) = Total Parking Construction Area ÷ Total Number of Car Parking Spaces

Industry Benchmark:
The accepted industry benchmark for car parking efficiency in residential apartment towers in India is 320 to 340 Sq.Ft per car. This accounts for the car slot itself, the proportionate share of the drive aisle, ramp area, structural columns, and other incidental areas within the parking podium or basement.

Parking TypeTypical Efficiency (Sq.Ft per Car)Remarks
Basement Parking (Standard)320 – 340Industry benchmark; optimal for column-free layouts
Podium Parking330 – 360Slightly higher due to structural transfer slabs
Stacked / Mechanical Parking180 – 220High-density; lower area per car but higher capex
Open Surface Parking280 – 310Most efficient but consumes ground-level open space

A parking efficiency of 320–340 Sq.Ft per car is considered the sweet spot for conventional basement and podium parking in residential towers. Values above 350 Sq.Ft per car indicate inefficient design — caused by poor column grid planning, excessive ramp lengths, or oversized drive aisles. Values below 300 Sq.Ft per car may indicate under-provision of drive aisles or non-compliance with NBC / local parking norms, which can create operational issues.

Key factors affecting parking efficiency include:

  • Column Grid: A well-planned column grid (typically 7.5m × 7.5m or 8m × 8m) allows for optimal two-way drive aisles and three cars per bay, which is the most efficient configuration.
  • Ramp Design: The number, width, and slope of ramps consume significant area. A single ramp serving a large parking floor is more efficient than multiple ramps.
  • Drive Aisle Width: A minimum 6.0m drive aisle is required for 90° parking. Wider aisles improve circulation but reduce efficiency.
  • Parking Slot Size: Standard parking slot dimensions in India are 2.5m × 5.0m (NBC norms). Compact slots (2.3m × 4.5m) improve density but are not preferred in premium developments.
  • Car Lift vs. Ramp: Car lifts in ultra-premium towers improve footprint efficiency but significantly increase cost per parking space.

Summary of Efficiency Ratios – Quick Reference

Efficiency RatioFormulaGood Benchmark
Carpet / Construction AreaCarpet Area ÷ Tower Construction Area × 10068% – 75% (mid-segment)
Carpet / FSI AreaRERA Carpet Area ÷ FSI Built-up Area × 10070% – 78% (mid-segment)
Car Parking EfficiencyTotal Parking Area ÷ No. of Car Spaces320 – 340 Sq.Ft per car

These efficiency ratios are essential inputs in a developer’s feasibility model. A project with poor efficiency ratios will have higher construction costs per unit of saleable area, reducing margins or forcing higher sale prices. Architects and planners must continually optimise these ratios during the design development stage to ensure the project remains both financially viable and functionally superior.

Also explore related articles on efficiency and feasibility:
📐 Real Estate and Construction Terminologies – Carpet Area, Construction Area, FSI Explained
📊 FSI in Real Estate – How is FSI Calculated in Mumbai?

So above are the critical factors for design of an apartment plan. Please let us know your comments and thoughts on the above parameters. Feel free to comment on any additional parameters, and we shall include in the article.

Also explore on Architectural Design Process for Residential Development

Best in Architecture,
Engineering & Construction

straight into your inbox!

Only 1 email per week!

Related Posts

Business Ideas

Mall design principles and cost

A comprehensive guide to mall design principles, key planning standards, Dubai Hills Mall as a case study, construction cost plan for a 50,000 sq ft mall in the UAE, and revenue projections for developers and investors.

Read More »
Scroll to Top